124 visiting now: 88 USA USA flag 30 Belgium Belgium flag 5 UK UK flag 1 Ireland Ireland flag 1 UAE UAE flag 1 Canada Canada flag

Highlighted Companies

Perlove Medical With Product Manufacturer Pld8000c - China

price: 100000.00 Dollar US$

① kV and mA values The combination of these two parameters constitutes the ability of the tube to release electrons and X-rays to effectively penetrate the photographed object, and determines the amount of heat released inside the tube.

The greater the mA and kV, the more heat is released.

Predicting the amount of heat generated helps to determine whether the dome tube is overheating during operation, and thus maintains and extends the life of the dome tube.

② Tube Power The rate of heat generation within the tube is equal to the electrical power given by the tube and is usually related to the formula (Power (W) = w x kVp x mA).

The higher the power, the shorter the life of the tube.

However, if there is not enough power, there may not be enough X-ray intensity to do the job, so operating the tube at the lowest available power extends its life.

Influence of tube voltage and tube current on X-ray intensity ③Anode target The anode target links the focal width, the projected spot size and the focal heat capacity.

In the case of a certain effective focal point, the smaller the target angle, the larger the actual focal point, the more unfavorable to the target surface heat dissipation, so the target angle is generally 6-17.5 °, and the anode target requires a large heat capacity, good resistance to thermal expansion.

④Anode heat capacity Focus (0.6~1.2) heat capacity, 200kHU, 300kHU, 400kHU and so on are more reasonable; Focus (0.3~0.8) heat capacity is 600kHU, 700kHU and above are more reasonable.

Among them, the heat capacity of the bulb represents the bearing capacity of the whole tube sleeve, which is related to the heat dissipation curve; the larger the diameter size of the target surface, the more obvious the heat dissipation effect.

⑤ Focus size Focus size is used to measure the spatial resolution presented by the tube, in order to obtain high quality image resolution, it is usually necessary to use a smaller focus size (micro-focus: less than 0.4mm; smaller focus: less than 1mm, micro-focus is usually used as a cardiovascular fluoroscopy tube more).

When shooting images, the smaller the focal point, the higher the resolution, but the power will also be reduced, the balloon can be a good solution to improve the power and reduce the contradiction between the focal point is extremely important.


Company Contact:


  • Phone: 18846759047

  • Address: No.97,Wangxi Road, Jiangning District,Nanjing, Nanjing, Jiangsu Province, China, China

  • Email: Email


Published date: January 10, 2024

  • Business Description: Founded in 2003, Perlove Medical is a high-tech enterprise integrating research and development, production, sales and after-sales service of medical X-ray imaging equipment and orthopedic surgical robots.

    Sales network covers the whole country, products are exported to more than 100 countries and regions.

    The company always adhere to independent research and development, scientific and technological innovation, customer demand-oriented, close to the clinical, to provide high-quality products and services for global medical institutions, promote the development of medical technology, so that more people enjoy high-quality medical services

Related listings



  • Perlove Medical Product Manufacturer With Low Moq
    Perlove Medical Product Manufacturer With Low Moq
    Prefabricated buildings and structures - Nanjing Perlove Medical Equipment Co.,ltd - China - January 10, 2024 - 100000.00 Dollar US$

    The parameters of the tube include structural parameters (tilt angle, focal point, external dimensions, weight, filtration equivalent of the tube wall, anode rotation speed, operating temperature and cooling form, etc.) and electrical parameters (fil...

  • Perlove Medical With Adequate Stock Pld7300b
    Perlove Medical With Adequate Stock Pld7300b
    Prefabricated buildings and structures - Nanjing Perlove Medical Equipment Co.,ltd - China - January 10, 2024 - 100000.00 Dollar US$

    PLX8600 Dynamic DR In recent years, there are more patients with deformities of the spine and lower limbs. Scoliosis deformity, which mostly occurs in adolescents, osteoarthritis, rheumatoid arthritis, and deformities of both lower limbs, such as int...

  • Perlove Medical With Oem Wholesale Best Quality Pld8000c
    Perlove Medical With Oem Wholesale Best Quality Pld8000c
    Prefabricated buildings and structures - Nanjing Perlove Medical Equipment Co.,ltd - China - December 26, 2023 - 100000.00 Dollar US$

    With the assistance of orthopedic surgical robots, only a few tiny incisions are usually required during surgery, which significantly reduces the amount of bleeding and radiation dose received by patients. In addition, it also speeds up postoperative...



Safe Trade Tips

  • Ask for business references and check them
  • Use a payment method that offers better protection for all such as Letters of credit and verified professional escrow services. Avoid payments in advance such as money transfers
  • Verify their business via their local Chamber of Commerce
  • Search the internet using their website address, their business name, their phone and fax numbers, and their email addresses to see if you can find any feedback about them.
  • Get to know more about scams and fraud to avoid: Internet Crime Complaint Center - Consumer Financial Protection Bureau
  • This site is never involved in any transaction, and does not handle payments, shipping, guarantee transactions, provide escrow services, or offer "buyer protection" or "seller certification"