Electrochemical Sensing Module

Chlorine (HOCl, HOBr or ClO2 ) & Temperature

/

KAPTA 2000-AC2 In-line Chlorine Sensors General description

The KAPTA 2000-AC2 probe has been specifically developed to measure free chlorine (HOCl) and temperature directly within a pressurised pipe for many applications including management and control of a drinking water network, real-time, rapid control of chemical dosing for industrial water processes and cleaning regimes and management of chlorine levels within swimming pools and spas.

/

The KAPTA 2000-AC2 is an amperometric sensor using a structured photo-polymerised membrane directly on the electrode which suppresses the well-known drawbacks of amperometric sensors with electrolyte, such as pressure and flow sensitivity, and enables the probe to be installed directly within pipes up to 10 bar flow pressure without flow or pressure control.

/

The sensor principal also eliminates the need for field re-calibration and on-going routine membrane replacement allowing both long-term stability of the signal and reduced maintenance costs.

The principal of the measurement is based on a Clark-type cell with a working, counter and reference electrode.

/

The sensor design includes a simple replaceable head which is easy to handle and requires no reagent or electrolyte.

As the lifetime of the sensor can vary with the application, this design allows more flexibility and price improvement for critical applications.

/

KAPTA 2000-AC2 In-line Chlorine Sensors Benefits

• Real-time water network monitoring

• No on-going membrane / electrolyte maintenance

• Chemical free operation

/

KAPTA 2000-AC2 In-line Chlorine Sensors Main features

• Amperometric sensor

• Measurement of the main disinfection species: HOCl, HOBr or ClO2

• User replaceable sensing head

• Inline monitoring at up to 10 bar pressure

• Easy conditioning

• > 1 year shelf life

/

KAPTA 2000-AC2 In-line Chlorine Sensors Typical applications

• Water quality control

• Drinking water security

• Industrial process control

• Chemical dosing measurement and control

• RO membrane security

• Swimming pool water quality

• Cooling towers

• Fish farming

/

KAPTA 2000-AC2 In-line Chlorine Sensors Specifications

• Maximum pressure: 10 bar • [Cl-]: > 2 mg/l • Minimum conductivity: 100 µS/cm • Response time: < 30 s • Minimum flow rate recommended: 0.03 m/s • Operating temperature range: 0 - 40°C​ • Temperature response time: < 15 s/°C • Weight: 175g


Company Contact:


  • Phone: 86-0755-83289036

  • Address: 16 Floor, Building #3, Zhongke Mansion, Gaoxin South 1st Rd, Hi-Tech Park, Nanshan, Shenzhen , Guangdong , China

  • Email: Email

Published date: March 21, 2018

  • Business Description: ISweek has been devoted to providing one-stop product distributing and purchasing solution and service for purchasers, suppliers, traders and manufactures from all over the world in industrial science and technology industry.

    We are able to provide high-quality original products and thorough technical support and after-sale service to our member users.

Related listings



  • As8900 4 In 1 Muilt Gas Monitor
    As8900 4 In 1 Muilt Gas Monitor
    Electrical equipment and components - Shenzhen week Technology Ltd - China - March 21, 2018 - check with company for price

    AS8900 4 in 1 Muilt Gas Monitor Introduction The AS8900 multi-gas monitor is a portable and handheld instrument that is capable to use continuously and simultaneously monitoring 4 gases: Oxygen, Combustile gas, Carbon Monoxide and Hydrogen Sulfide. E...

  • Ar8500 Ammonia Nh3 Gas Detector
    Ar8500 Ammonia Nh3 Gas Detector
    Electrical equipment and components - Shenzhen week Technology Ltd - China - March 21, 2018 - check with company for price

    AR8500 Ammonia Gas Detector Product description: Ammonia analyzer is a continuous quantitative analysis of formaldehyde concentration apparatus, the apparatus using imported high precision electrochemical principle formaldehyde sensor, fast response ...

  • Psc T54u Non Contact Infrared Pyrometer For Glass Industry Applications
    Psc T54u Non Contact Infrared Pyrometer For Glass Industry Applications
    Electrical equipment and components - Shenzhen week Technology Ltd - China - March 15, 2018 - check with company for price

    PSC-T54U Infrared Pyrometer for Glass Industry Applications / PSC-T54U Non-Contact Infrared Pyrometer Description The digital PSC-T54U is designed specifically for glass surface applications. Offering a wide temperature range from 350° to 1200°C, it ...



Safe Trade Tips

  • Ask for business references and check them
  • Use a payment method that offers better protection for all such as Letters of credit and verified professional escrow services. Avoid payments in advance such as money transfers
  • Verify their business via their local Chamber of Commerce
  • Search the internet using their website address, their business name, their phone and fax numbers, and their email addresses to see if you can find any feedback about them.
  • Get to know more about scams and fraud to avoid: Internet Crime Complaint Center - Consumer Financial Protection Bureau
  • This site is never involved in any transaction, and does not handle payments, shipping, guarantee transactions, provide escrow services, or offer "buyer protection" or "seller certification"