Cooling Water Chiller Sundi 45 300 - China
price: contact company for price
It is important to choose the suitable heat conduction medium, to make sure that system works stably.
To choose the suitable medium according to the working temperature of the system is essential.
How to Determine Freezing Water Flow Rate? A lot of people will ask such a question when they buy a cold water machine -- how do you determine the freezing water flow of a refrigerated water unit? So which aspects should we consider the cold water flow?
1 - Water pressure test of the unit in and out of the water pipe.
Detect the pressure value of the in- and out-water, then refer to instruction about the water flow under this circumstance and determine whether the water system is normal by looking at the description in the corresponding table or flow diagram of the unit.
This difference is also used to determine which part of the water pipeline has a large resistance and make corresponding rectification plan and action.
2 - The air inlet temperature of the compressor should be tested only when the refrigeration operation is carried out.
If the temperature of the refrigerated water chiller is tested lower than zero after running for 30 minutes, then water flow is not enough on water side heat exchanger which causes evaporation temperature and pressure to fall and cause freon in evaporator flow to the compressor suction duct in evaporation heat.
That brings about the fact that the compressor suction temperature below zero.
In addition, the evaporation pressure and evaporation temperature caused by low temperature setting should be excluded.
However, the low-temperature unit can be considered normal as long as there is 6 ~ 8 ℃ overheat of compressor suction.
So under normal water flow, the compressor suction temperature generally will be greater than 0 ℃.
Temperature lower than this value should be ruled out water system problems.
3 - The current needs to be tested when the pump runs.
By detecting the current of the pump of water industrial chiller and comparing with rated current, you can determine the actual water flow, whether its water flow is big or small.
Refer to the parameters above, you can draw an exact water system testing analysis report.
Company Contact:
- Phone: 0510-82303782
- Address: No.10, Zhenfa No.1 Road, Shuofang Street, New District, Wuxi, Jiangsu ,China.Zip Code:214142, wuxi , jiangsu , China
- Email:
- Website: http://www.lneya.com/
Published date: July 14, 2019
- Business Description: Wuxi Guanya Refrigeration Technology Co., Ltd. Specialized in refrigeration equipment,Ultra-low temperature freezer, cooling and heating temperature control system, heating circulation system, explosion-proof electric equipment.
Automatic integrated disparate control system, laboratory apparatus.
We are the technology leader for high precision thermoregulation solutions in Research and Development Industry.
Our products ensure precise temperature control throughout the whole world in laboratories, pilot plants and production processes.
Our product range offers temperature control solutions for applications from -152 to +350℃.
Our Products:
- Test Chamber
- Glycol Cooling Heating Control System
- High Low Temperature Test Chamber
- Thermal Shock Chamber For Sale
- Heating Circulator Uc
Related listings
-
Lab Water Chiller Sundi 60 300Industrial process machinery - Wuxi Guanya Refrigeration technology co., ltd - China - July 14, 2019 - contact company for price
Lab Water Chiller SUNDI -60℃~300℃ A fully closed piping design, high efficiency plate heat exchanger used to reduce the demand for the thermal fluid utilization while providing the system to achieve the rapid ups and downs in temperature The whole sy...
-
Industrial Chiller System Sundi 25 300Industrial process machinery - Wuxi Guanya Refrigeration technology co., ltd - China - July 14, 2019 - contact company for price
Use high temperature resistant low-temperature magnetic drive pump or a leak-free high and low-temperature shield-driven pump, reduce the risk of system leakage. At the same time, the screw water chiller system has the advantages of low noise and big...
-
Air Water Chiller Sundi 40 To 200 For Two ReactorsIndustrial process machinery - Wuxi Guanya Refrigeration technology co., ltd - China - July 14, 2019 - contact company for price
Air Water Chiller Display function Cooling heating Temperature Control System Display – The Refrigeration system's multi-image displays various information. How Does the Industrial Chiller Release Gas? 1. When air is released by air separator, the re...
Safe Trade Tips
- Ask for business references and check them
- Use a payment method that offers better protection for all such as Letters of credit and verified professional escrow services. Avoid payments in advance such as money transfers
- Verify their business via their local Chamber of Commerce
- Search the internet using their website address, their business name, their phone and fax numbers, and their email addresses to see if you can find any feedback about them.
- Get to know more about scams and fraud to avoid: Internet Crime Complaint Center - Consumer Financial Protection Bureau
- This site is never involved in any transaction, and does not handle payments, shipping, guarantee transactions, provide escrow services, or offer "buyer protection" or "seller certification"