Red Color Switchgear Epoxy Resin Cast Bushing Heat Resistance 4000a 10kv - China
price: contact company for price
CHN3-12Q/280 4000A 10kV Epoxy Resin Insulators Contactor Box Spolt Bushings Gas, Steam, dust without seriously affecting the insulation of the contact box No exploration or corrosive submission.
Technical Data & Requirements Requirement Technical data and requirements 1 - Contact box and contact should be able to withstand frequency test voltage(effectiveness) 42 KV, 5 minutes, lightning shock(peak) 75 KV; The label contact to earth call with power freedom test volume of 42 KV for 5 minutes and Lightning impact vplage(peace value) of 75KV; The temperature rise of the end of the contact box at the end of the line under long-term operation does not exceed 65 under the rated electricity; The experience of lead-out final call not more than 65 C if the contact box is used for long time in rate current con the wall-piercing sleeve is used to increase the insulation function of the mother-row in the cabinet and play a certain supporting role.
In the middle, in the end.
Insulators only act as support, sometimes using a belt point sensor directly instead of an insulator as well as as as sensors.
The cabinet is large but easier to maintain.
Medium case is large, but maintenance is more convenient.
Ring case is small, but maintenance is not convenient.
(Schneider SM6 now has a high voltage loop switch cabinet with special SFset circuit breaker.
SGN1A-12(Z) small fixed separator, developed jointly, can achieve the basic function of medium case using ABB LEG(Z1)-12 circuit breaker, but the ring net case or small fixed compartment can be set up as a low voltage circuit breaker.
Only according to the fixed mode of installation, so that when the circuit breaker failure, need to be replaced immediately, not only need to cut off the upper power supply, but also trouble to replace.
It is convenient to replace the handcar switch.
- - - - Item | Technical data | Rated voltage (KV) | 3.6 | 7.2 | 12 | 24 | 40.5 | Rated frequency(Hz) | 50 | Insulator(capacity) | insulating | Frequency withstand voltage 5 min (KV) | 25 | 32 | 42 | 68 | 100 | Frequency withstand voltage 1 min (V) | 2000 | Lighting impulse withstand voltage (KV) | 40 | 60 | 75 | 125 | 185 | Rated Current | 4000A | Dispute bend (N) | 10000 | | | - - - -
Company Contact:
- Posted By: WENZHOU QIUPU ELECTRIC POWER CO., LTD.
- Phone: 86-577-61668158
- Address: Room 102 , Building 7 , No. 1. Xinhe Road YueCheng Street , Yueqing City , Zhejiang P.R., China-3256, Yueqing , Zhejian , China
- Email:
- Website: https://www.epoxyresininsulator.com
Published date: April 9, 2018
- Business Description: Our products are widely used in financial, communications, municipal, transportation, power, construction, aerospace, industrial control and other important areas, has won the majority of users praise and signed a long-term cooperation agreement.
Related listings
-
Apg Technology Epoxy Resin Bushing 3150a 10kv For Handcart Type SwitchgearExtrusions - WENZHOU QIUPU ELECTRIC POWER CO., LTD. - China - April 9, 2018 - contact company for price
CHN3-12Q/250 3150A 10kV Epoxy Resin Insulators Spolt Bushings We are specialty on epoxy resin medium voltage and high voltage components, such as 10KV, 24 KV and 40.5KV Circuit Breaker, Load breaker switch, Disconnecting Switch, Epoxy resin switchgea...
-
Electrical Epoxy Resin Insulator Contact Box For Switchgear 630a 1250a 10kvExtrusions - WENZHOU QIUPU ELECTRIC POWER CO., LTD. - China - April 9, 2018 - contact company for price
CHN3-12Q/150-630-1250A 10kV Epoxy Resin Insulators Contactor Box Spolt Bushings General Description of the Contact BOX Series 1. The contact box is the pressure gel molding structure of epoxy resin APG process, which is used for various kinds of hand...
-
Indoor Vcb Copper Electrical Contacts Arm Type 42x315mm 630a 2000aExtrusions - WENZHOU QIUPU ELECTRIC POWER CO., LTD. - China - April 9, 2018 - contact company for price
630A Red Copper Arm Contact 42X315 with Indoor Vacuum Circuit Breaker Red copper Arm contact is fit with high voltage indoor vacuum circuit breaker, its fix with clubs contact and connect with switchgear equipment . The magnetic field produced by the...
Safe Trade Tips
- Ask for business references and check them
- Use a payment method that offers better protection for all such as Letters of credit and verified professional escrow services. Avoid payments in advance such as money transfers
- Verify their business via their local Chamber of Commerce
- Search the internet using their website address, their business name, their phone and fax numbers, and their email addresses to see if you can find any feedback about them.
- Get to know more about scams and fraud to avoid: Internet Crime Complaint Center - Consumer Financial Protection Bureau
- This site is never involved in any transaction, and does not handle payments, shipping, guarantee transactions, provide escrow services, or offer "buyer protection" or "seller certification"